9F,Bldg.A Dongshengmingdu Plaza,No.21 Chaoyang East Road,Lianyungang Jiangsu,China +86-13951255589 [email protected]
Path length:5mm, 10mm,20mm, 30mm and can be customized
Capacity : 0.035ml, 0.07ml, 0.14ml, 0.21ml and can customize according to clents’ reaquirements
Transmittance Range: Optical glass cell transmission at 350nm is about 82%ES quartz cell transmission at 200nm is about 80%
Structural Properties:Standard tolerance is +/-0.5mm and Precise dimensional tolerance +/0.01mm
Heat Resistance:-40℃~+200℃, some models support 121℃ autoclaving
Product Details
A black-walled flow cuvette is a specialized optical vessel designed for high-precision spectrophotometric and fluorometric measurements in continuous flow systems. Also called a black-sided flow cell or masked flow-through cuvette, it features opaque, light-absorbing black walls on all sides except the two clear optical windows for the light path. This design eliminates stray light and minimizes internal light scattering, significantly improving signal-to-noise ratio and measurement accuracy. Every flow cuvette is precision machined and optically polished, with path length and capacity customized to the instrument platform.
1.1 Structural Design
The core structure of a black-walled flow cuvette is a precision-machined flow channel with inlet and outlet ports, typically threaded fittings or Luer connectors. The black wall effect is achieved by two methods: black masking, where quartz or glass is etched or coated with an opaque black material on non-optical surfaces; and black housing, where the flow cell is encased in a rigid black polymer such as PEEK or PTFE, or a metal housing that shields the sides while exposing only the optical windows.
1.2 Material Composition
The optical windows are typically made from fused silica quartz for UV-Vis transmission of 190-2500 nm, or optical glass for visible-range applications of 340-2500 nm. The internal flow channel is smooth and chemically inert to prevent sample adsorption and facilitate cleaning, so the flow cuvette keeps a stable baseline. Material choice for the flow cell depends on wavelength and solvent compatibility. Choose the flow cuvette by wavelength range.
2.1 Continuous Automated Measurement
Flow cuvettes enable continuous automated measurement, eliminating repeated manual sample handling and reducing workload in high-throughput laboratories and process control systems. Flow cells suit inline quality monitoring. The flow cuvette fits standard holders.
2.2 Improved Measurement Stability
Because the sample is continuously refreshed inside the flow cell, concentration gradients and evaporation effects are minimized, helping maintain a stable baseline during kinetic studies.
2.3 Rapid Sample Switching
When the flow cell is connected to an autosampler or flow-injection system, samples can be analyzed sequentially without interrupting the instrument, reducing cross-contamination risk with proper flushing. Flow cells support automated sampling schedules.
2.4 Low Internal Volume
Small-volume flow cells reduce carryover between samples and allow faster equilibration when the mobile phase or sample composition changes. The compact flow cell reduces dead volume. Flow cells are available in disposable versions. The flow cuvette also suits micro-volume analysis.
For quartz and fused silica flow cuvettes, high-purity silica raw materials are selected to ensure low impurity content and stable UV transmission. The optical windows are cut, ground and polished to the required flatness and parallelism, because any deviation can cause light scattering or baseline drift. The flow channel is produced by precision machining or drilling, and quartz or glass components are joined by optical bonding, sintering or fusion. After assembly, the transparent surfaces are polished to optical-grade quality and ports are fitted with standard connectors. Finished flow cells are inspected for dimensional accuracy, optical transmission, leakage tightness and batch consistency, and every flow cell is leak-tested before packing. The flow cuvette is available in glass and quartz.
4.1 UV-Vis Absorbance Detection
Used in spectrophotometers and flow-injection systems for continuous monitoring of liquid samples in UV, visible and near-infrared regions. The flow cell connects to pumps and autosamplers.
4.2 Fluorescence Detection
Suitable for fluorescence spectrometry, HPLC fluorescence detectors and capillary electrophoresis detection, where black walls reduce excitation-light scatter and background noise. Fluorescence flow cells give low background signal.
4.3 HPLC and UHPLC Detector Cells
Applied as optical flow cells in liquid chromatography systems, the flow cuvette monitors eluent absorbance or fluorescence in real time.
4.4 Flow-Injection and Continuous-Flow Analysis
Widely used in automated chemical analyzers for water quality testing, nutrient determination and industrial process monitoring. Continuous-flow analyzers rely on rugged flow cells for unattended runs. Black-wall flow cuvettes block ambient light.
Standard flow cell path lengths are listed below, with the optical materials of the black-walled flow cuvette.
|
|
|
|
Optical Glass |
G |
at 350nm approx. 82% |
at 350nm max. 0.5% |
ES Quartz Glass |
Q |
at 200nm approx. 80% |
at 200nm max. 0.5% |
IR Quartz Glass |
I |
at 2730nm approx. 88% |
at 2730nm max. 0.5% |
Path length of 5mm, 10mm, 20mm and 30mm is available with capacity of 0.035ml, 0.07ml, 0.14ml and 0.21ml, and custom flow cell sizes can be produced. Standard tolerance is +-0.5mm and precise dimensional tolerance is +-0.01mm. Heat resistance covers -40 C to +200 C, and some models support 121 C autoclaving.
Development History
Lianyungang Haibo Technology has built ceramic and special-glass production lines over the past decades, with eight registered trademarks and forty technical patents behind our in-house R&D. The flow cuvette line grew from the same precision-material platform that serves our quartz cuvettes and special glass products, so optical tolerance and surface quality follow one consistent standard on every flow cuvette we ship.
Patents and Certification
We hold a range of global certifications including IATF16949, CE, EMC, LVD, RoHS, FDA, MSDS, ISO 9001, SGS and TUV, together with eight registered trademarks and forty technical patents supporting independent R&D. Our proprietary core technologies run through all product lines - porous ceramics, industrial ceramic components, special glass, metallized ceramics, liquid absorption cotton, ozone generators and silicone goods - and every black-walled flow cuvette is produced in accordance with international quality standards before delivery.
Package
We adopt standardized packaging tailored to the product to effectively prevent collision, extrusion, dust and moisture damage. Each black-walled flow cuvette is protected against scratches and contamination during transit. With a mature global transportation system and strict shipment inspection, we keep orders intact over long-distance delivery and provide safe, efficient one-stop logistics service.
Services
We provide fast, accurate quotations. Flexible OEM & ODM customization is available for black-walled flow cuvette size, dimensions, surface finish, packaging and branding.
We keep clients updated with full production progress throughout the order cycle, and our QC team carries out a strict pre-shipment inspection to help ensure goods comply with your quality standards before delivery.
We prepare a full set of standard export documents including commercial invoice, packing list, certificate of origin and related certification papers, to support smooth customs clearance to destinations worldwide.
Sea freight, air freight and express delivery are offered to match your schedule and budget, with real-time cargo tracking so you can monitor shipment status anytime.
We support mainstream cross-border settlement methods such as T/T and L/C to reduce transaction risk on bulk orders.
Our professional after-sales team offers timely technical and business support all year round, and we maintain steady long-term supply capacity to back up your continuous market demand for black-walled flow cuvette products.
FAQ
Answer: Yes. We accept technical drawings in mainstream file formats as well as actual physical samples. Before formal production, our engineering team provides a DFM feasibility review for your reference.
Answer: Sample and custom lead time are confirmed per drawing and project scope. Mass production lead time is typically 7-20 working days, depending on part complexity and order quantity; we will quote a specific cycle on your inquiry.
Answer: We offer flexible MOQ for customized items and try to keep the minimum workable for small-batch trials, while still supporting stable mass production for long-term bulk demand.
Answer: We support one-stop customization including size, shape, appearance, precision tolerance, surface treatment and special processing, plus custom engraved logo and exclusive packaging on request.
Answer: Yes. We cooperate with authorized third-party testing bodies such as SGS and BV and can supply inspection reports and material certification documents as required.